SVI0.S08 VALVE SERIES
SAE Cartridge - 250 bar
Directional Valve - 3/2 Seated Type
HYDRAULIC SYMBOL
Cross section
Cavity
SAE08-2
DESCRIPTION
A solenoid valve operated, 3 way 2 positions, seated type, direct acting, bi-directional blocking, screw-in hydraulic directional cartridge valve.
In the de-energized mode, the SVI0.S08 allows flow bi-directionally between ports 1 and 2, while blocking flow at 3. In the energized mode,
bi-directional flow is allowed between ports 3 and 2, while flow is blocked at 1 with extremely low leakage. Even if port 1 and 3 may be fully
pressurized they are not intended to be used as the inlet. The rigid design using a 1-piece body contributes to minimize the effect of
eccentricities in cavity and provides great reliability. Low pressure drop thanks to optimized flow path.
TECHNICAL DATA
0,25 cm
3
/ min @ 250 bar
EXTERNAL COMPONENT TREATMENT
Zn/Fe - standard (96h)
Zn/Ni (720h) (Upon customer request)
MAXIMUM FLOW
10 l/min
MAXIMUM OPERATING PRESSURE
250 bar
WEIGHT
0,231 kg
SEAL KIT CODE
SK.035 and SK.027 (coil) (standard sealing NBR-BUNA-N)
OIL TESTING CONDITIONS
ISO VG 46 cSt
TECH. SPEC. FOR CHARACTERIZATION
see page 689
ORIENTATION
No restrictions
INSTALLATION TORQUE
35-40 Nm
FILTRATION
20/18/15 ISO 4406 (maximum filtration admitted)
VISCOSITIES
7,4 to 420 cSt
FLUIDS
Mineral - based or synthetics with lubricating properties
OIL TEMPERATURE RANGE
-30° C to 110° C
O-RING TEMPERATURE RANGE
-30° C to 110° C (standard sealing NBR - BUNA - N)
-35° C to 140° C (HNBR - Upon customer request)
-23° C to 225° C (FKM - Upon customer request)
Hex.24
MAXIMUM INTERNAL LEAKAGE
85% of nominal
MINIMUM PULL-IN VOLTAGE
COIL
20,5 W (Upon customer request - for more details see page 595)
22 W (for more details see page 595)
S V I 0
.
ORDERING CODE
S 0 8 0
*
. .
0 0
*
Valve basic code
Size
Marking
0 = Standard factory marking.
Customized marking can be done
upon request.
MANUAL OVERRIDE
3/4-16 UNF with Ø15,87 and
Ø14,27 nose sizes
Model code Type of override
0 No override
3 Push pin
4 Push knob
8 Screw
Note
Costumized nut can
be selected
SOLENOID Valves
Specifications may change without notice.
1 2
SOLENOID Valves
Energized
De-Energized
Performance Limits
The performance chart illustrates flow handling capacity 2 to 3 and 3 to 2 (energized) 2 to 1 and 1 to 2 (de-
energized).
p/Q curves are recorded at TOil = 40°C and 46 cSt.
NOTE
3 4
SVI0.S08 GRAPHS
The performance chart illustrates flow handling capacity 2 to 3 and 3 to 2
(energized) 2 to 1 and 1 to 2 (de-energized).
p/Q curves are recorded at TOil = 40°C and 46 cSt.